Preview

Measurement Standards. Reference Materials

Advanced search

Multifunctional state primary power standard in the frequency range from 1 to 2500 Hz, GET 153-2019

https://doi.org/10.20915/2687-0886-2020-16-1-7-16

Abstract

This paper describes measurement techniques, structure, technical characteristics and results of the uncertainty analysis for primary multifunction power standard in the frequency range from 1 Hz to 2500 Hz.

About the Authors

G. B. Gubler
D. I. Mendeleyev Institute for Metrology
Russian Federation

Gleb B. Gubler – PhD (Engineering), head of power and energy standards laboratory

19 Moskovsky ave., St. Petersburg, 190005



A. Yu. Nikitin
D. I. Mendeleyev Institute for Metrology
Russian Federation

Alexander Yu. Nikitin – deputy head of power and energy standards laboratory

19 Moskovsky ave., St. Petersburg, 190005



E. Z. Shapiro
D. I. Mendeleyev Institute for Metrology
Russian Federation

Efim Z. Shapiro – PhD (Engineering), principal research scientist of electric power and energy standards laboratory, honoured metrologist of the Russia

19 Moskovsky ave., St. Petersburg, 190005



N. S. Alekseeva
D. I. Mendeleyev Institute for Metrology
Russian Federation

Nadezgda S. Alekseeva – research scientist of electric power and energy standards laboratory

19 Moskovsky ave., St. Petersburg, 190005



References

1. Shapiro E. Z., Belov V. S., Pushkareva O. G., Nikolaeva G. V. National special standard for the unit of electrical power. Izmer. Tekhn.=Measurement Techniques. 1990; 32(8); 3–5. (In Russ.)

2. Gubler G. B., Nikitin A. Y., Shapiro E. Z. National primary standard for the unit of electrical power at frequencies from 1 to 2500 Hz, GET 153-2012. Measurement Techniques. 2016;59(1);3–7. https://doi.org/10.1007/s11018-016-0906-4 (In Russ.)

3. Gubler G. On the use of windows for measurements of R.M.S., active power and harmonic parameters. CPEM Digest. 2008;206– 2017. https://doi.org/10.1109/CPEM.2008.4574725

4. Grandke T. Interpolation Algorithms for Discrete Fourier Transforms of Weighted Signals. IEEE Transactions on Instrumentation and Measurement. 1983;32(2):350–355. https://doi.org/10.1109/TIM.1983.4315077

5. Zakharov B. V., Shatalov A. N. Pogreshnosti dvukhstupenchatogo transformatora toka [Errors of a two-stage current transformer]. Izmer. Tekhn.=Measurement Techniques. 1980; (4). pp. 41-42 (In Russ.)

6. V’iukhin V. N., Popov Iu. A., Tani Iu. L. Issledovanie metoda kogerentnoi vyborki dlia testirovaniia vysokorazriadnykh ATsP [Research of the coherent sampling method for testing high-bit ADCs]. Avtometriia. 1997;(5). (In Russ.)

7. Demirchian K. S., Neiman L. R., Korovkin N. V., Chechurin V. L. Teoreticheskie osnovy elektrotekhniki [Theoretical foundations of electrical engineering]. In 3 volumes. Textbook for universities. T. 1. 4th ed. Sankt-Peterburg, 2003. 463 p.

8. GOST 30804.4.30–2013 (IEC 61000–4–30:2008) Electric energy. Electromagnetic compatibility of technical equipment. Power quality measurement methods. Standartinform Publ., 2014. 9 p. (In Russ.).

9. Georgakopoulos D., Budovsky I., Benz S. P. Gubler G. Josephson arbitrary waveform synthesizer as a reference standard for the measurement of the phase of harmonics in distorted waveforms. In IEEE Transactions on Instrumentation and Measurement, 2019;68(6): 1927–1934. https://doi.org/10.1109/TIM.2018.2877828

10. Gubler G. Extension of a waveform reconstruction algorithm for a DVM with an Integrating ADC. Conference on precision electromagnetic measurements (CPEM 2018). Paris, 2018, pp. 1–2. https://doi.org/10.1109/CPEM.2018.8500991

11. Aguilar J. D., Salinas J. R., Kieler O. F., Caballero R., Behr R., Sanmamed Y. A., Méndez Á. R. Characterization of an analog-to-digital converter frequency response by a Josephson arbitrary waveform synthesizer. Measurement Science and Technology 2019;30(3):035006. https://doi.org/10.1088/1361-6501%2Faafb27

12. Katkov A., Shevtsov V., Gubler G. VNIIM 10 V programmable josephson voltage standard. Conference on Precision Electromagnetic Measurements (CPEM 2018). Paris, 2018, pp. 1–2. https://doi.org/10.1109/CPEM.2018.8500892


Review

For citations:


Gubler G.B., Nikitin A.Yu., Shapiro E.Z., Alekseeva N.S. Multifunctional state primary power standard in the frequency range from 1 to 2500 Hz, GET 153-2019. Measurement Standards. Reference Materials. 2020;16(1):7-16. (In Russ.) https://doi.org/10.20915/2687-0886-2020-16-1-7-16

Views: 1299


ISSN 2687-0886 (Print)