<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">rmjournal</journal-id><journal-title-group><journal-title xml:lang="ru">Эталоны. Стандартные  образцы</journal-title><trans-title-group xml:lang="en"><trans-title>Measurement Standards. Reference Materials</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2687-0886</issn><publisher><publisher-name>D. I. Mendeleyev Institute for Metrology</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.20915/2077-1177-2023-19-4-63-71</article-id><article-id custom-type="elpub" pub-id-type="custom">rmjournal-422</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Стандартные образцы</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Reference materials</subject></subj-group></article-categories><title-group><article-title>Стандартные образцы поглощенной дозы: расширение динамического диапазона и улучшение точности измерений</article-title><trans-title-group xml:lang="en"><trans-title>Reference Materials of Absorbed Dose: Expanding Dynamic Range and Improving Measurement Accuracy</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Тенишев</surname><given-names>В. П.</given-names></name><name name-style="western" xml:lang="en"><surname>Tenishev</surname><given-names>V. P.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Тенишев Владимир Петрович – канд. физ.-мат. наук, старший научный сотрудник лаборатории технических и радиотехнических измерений</p><p>141570, Московская область, п. Менделеево</p></bio><bio xml:lang="en"><p>Vladimir P. Tenishev – Cand. Sci. (Phys.-Math.), Senior Researcher, Laboratory of Technological Dosimetry</p><p>Moscow region, Mendeleevo, 141570</p></bio><email xlink:type="simple">tenishev@vniiftri.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГУП «Всероссийский научно-исследовательский институт физико-технических и радиотехнических измерений»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>All-Russian Scientific Research Institute of Physical-Technical and Radio-Technical Measurements (VNIIFTRI)</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2023</year></pub-date><pub-date pub-type="epub"><day>24</day><month>09</month><year>2023</year></pub-date><volume>19</volume><issue>4</issue><fpage>63</fpage><lpage>71</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Тенишев В.П., 2023</copyright-statement><copyright-year>2023</copyright-year><copyright-holder xml:lang="ru">Тенишев В.П.</copyright-holder><copyright-holder xml:lang="en">Tenishev V.P.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.rmjournal.ru/jour/article/view/422">https://www.rmjournal.ru/jour/article/view/422</self-uri><abstract><p>Установление и контроль метрологических характеристик измерений поглощенных доз ионизирующих излучений в диапазоне 0,01 и 200 кГр стандартными образцами – актуальная задача в силу их широкого применения в различных отраслях промышленности. Наиболее удобным средством метрологического обеспечения при проведении передачи единицы мощности поглощенной дозы интенсивного фотонного, электронного и бета-излучений в радиационных технологиях к средствам измерений являются стандартные образцы с установленной метрологической прослеживаемостью до международной системы единиц SI.</p><p>В настоящем исследовании рассмотрен и апробирован способ расширения динамического диапазона измерения поглощенной дозы высокоинтенсивного ионизирующего излучения радиохромными пленочными дозиметрическими системами. Проведена оценка точности (неопределенности) измерений дозы в зависимости от начальной оптической плотности радиационно-чувствительного слоя радиохромной композиции. Показана возможность расширения дозных и улучшения метрологических характеристик существующих стандартных образцов поглощенной дозы (по воде) для применения в качестве вторичных эталонов (Мер) поглощенной дозы ионизирующего излучения, воспроизводящих и (или) хранящих одну или несколько точек выбранной шкалы измерений поглощенной дозы с повышенной точностью (неопределенностью) измеряемых значений поглощенной дозы (по воде) в расширенном динамическом диапазоне.</p></abstract><trans-abstract xml:lang="en"><p>Establishment and control of metrological characteristics of measurements of absorbed ionizing radiation doses in the range of 0.01 and 200 kGy by reference materials is an urgent task due to their wide application in various industries. The most convenient means of metrological support for transferring a unit of absorbed dose rate of intense photon, electron, and beta radiation to measuring instruments in radiation technologies are reference materials with established metrological traceability to the International System of Units (SI). In the present study, a method for expanding the dynamic range of measuring the absorbed dose of high-intensity ionizing radiation by radiochromic film dosimetry systems was considered and tested. The accuracy (uncertainty) of dose measurements was estimated depending on the initial optical density of the radiation-sensitive layer of the radiochromic composition. The possibility of expanding the dose characteristics and improving the metrological characteristics of the existing reference materials of absorbed dose (in water) for use as secondary standards (Measures) of the absorbed dose of ionizing radiation reproducing and (or) storing one or more points of the selected measurement scale of the absorbed dose with increased accuracy (uncertainty) of the measured values of the absorbed dose (in water) in an extended dynamic range was shown.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>радиохромная пленка</kwd><kwd>радиационно-чувствительная композиция</kwd><kwd>оптическая плотность</kwd><kwd>спектрофотометр</kwd><kwd>стандартный образец</kwd><kwd>поглощенная доза</kwd><kwd>многослойная комбинация стандартных образцов поглощенной дозы</kwd></kwd-group><kwd-group xml:lang="en"><kwd>radiochromic film</kwd><kwd>radiation-sensitive composition</kwd><kwd>optical density</kwd><kwd>spectrophotometer</kwd><kwd>reference material</kwd><kwd>absorbed dose</kwd><kwd>multilayer combination of absorbed dose reference materials</kwd></kwd-group><funding-group><funding-statement xml:lang="ru">Автор выражает благодарность сотрудникам лаборатории технологической дозиметрии ФГУП «ВНИИФТРИ» за содействие и поддержку при выполнении данной работы.</funding-statement><funding-statement xml:lang="en">All measurements were carried out using the equipment of the All-Russian Scientific Research Institute of Physical, Technical and Radio Engineering Measurements.</funding-statement></funding-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Обеспечение единства измерений в радиационных технологиях / Р. А. Абдулов [и др.] // Альманах современной метрологии. 2015. № 2. С. 198–206.</mixed-citation><mixed-citation xml:lang="en">Abdulov R. A., Aleikin V. V., Generalova V. V., Gromov A. A., Gurskii M. N., Emel’ianenko I. A. et al. Ensuring the uniformity of measurements in radiation technologies. Al”Manac of Modern Metrology. 2015;2:198–206. (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Государственный первичный специальный эталон единицы мощности поглощенной дозы интенсивного фотонного, электронного и бета-излучений для радиационных технологий ГЭТ 209-2014 / В. В. Алейкин [и др.] // Альманах современной метрологии. 2015. № 5. С. 54–74.</mixed-citation><mixed-citation xml:lang="en">Aleykin V. V., Generalova V. V., Gromov A. A., Gurskiy M. N., Zhanzhora A. P., Emel’yanenko I. A. et al. National primary special standard for the unit of absorbed dose rate of intense photon, electron, and beta radiation for radiation technologies GET209–2014. Al”Manac of Modern Metrology. 2015;5:54–74. (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Коваленко О. И., Тенишев В. П. Средства измерений для контроля поглощенной дозы при радиационной обработке пищевой и сельскохозяйственной продукции // Ядерно-физические исследования и технологии в сельском хозяйстве: сборник докладов Международной научно-практической конференции, Обнинск, 16–18 сентября 2020 г. Обнинск: ФГБНУ ВНИИРАЭ, 2020. С. 335–337.</mixed-citation><mixed-citation xml:lang="en">Kovalenko O. I., Tenishev V. P. Measuring instruments for monitoring the absorbed dose during radiation processing of food and agricultural products. In: Nuclear physics research and technologies in agriculture: collection of reports of the International Scientific and Practical Conference, 16–18 September 2020, Obninsk, Russia. Obninsk: RIRAE; 2020. P. 335–337. (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Громов А. А., Жанжора А. П., Коваленко О. И. Применение стандартных образцов поглощенной дозы при валидации процессов радиационной стерилизации медицинских изделий и радиационной обработки пищевой продукции // Эталоны. Стандартные образцы. 2021. Т. 17, № 4. С. 23–32. https://doi.org/10.20915/2687-0886-2021-17-4-23-32</mixed-citation><mixed-citation xml:lang="en">Gromov A. A., Zhanzhora A. P., Kovalenko O. I. Application of certified reference materials of absorbed dose for process validation of irradiation of medical supplies and food products. Measurement Standards. Reference Materials. 2021;17(4):23–32. https://doi.org/10.20915/2687-0886-2021-17-4-23-32 (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Tenishev V. P., Emelyanenko I. A. Radiation-sensitive film compositions for measuring absorbed doses within the 100-1000 Gy range. In: Medvedevskikh S., Kremleva O., Vasil’eva I., Sobina E. (eds.). Reference Materials in Measurement and Technology. RMMT 2018. Springer, Cham. 2020. https://doi.org/10.1007/978-3-030-32534-3_13</mixed-citation><mixed-citation xml:lang="en">Tenishev V. P., Emelyanenko I. A. Radiation-sensitive film compositions for measuring absorbed doses within the 100-1000 Gy range. In: Medvedevskikh S., Kremleva O., Vasil’eva I., Sobina E. (eds.). Reference Materials in Measurement and Technology. RMMT 2018. Springer, Cham. 2020. https://doi.org/10.1007/978-3-030-32534-3_13</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Тенишев В. П. Спектральные, дозиметрические и метрологические характеристики радиохромных радиационно-чувствительных композиций // Измерительная техника. 2020. № 8. С. 59–65. https://doi.org/10.32446/0368–1025it.2020-8-59-65</mixed-citation><mixed-citation xml:lang="en">Tenishev V. P. Spectral, dosimetric, and metrological characteristics of radiochromic radiation-sensitive compositions. Measurement Techniques. 2020;8:59–65. https://doi.org/10.32446/0368–1025it.2020-8-59-65 (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Тенишев В. П. Спектральные и дозиметрические свойства многослойных структур радиохромных эталонов поглощенной дозы // Физический журнал: серия конференций. 2022. Сер. 2192 012017. https://doi.org/10.1088/1742–6596/2192/1/012017</mixed-citation><mixed-citation xml:lang="en">Tenishev V. P. Spectral and dosimetric properties of multilayer structures of radiochromic absorbed dose reference materials. Journal of Physics: Conference Series. 2192 012017. 2022. https://doi.org/10/1088/1742–6596/2192/1/012017</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
